site stats

Cylindrical rotor alternators have mcq

WebMaximum power in cylinder rotor alternator occurs at load angle of __________ a) 90 degree b) 45 degree c) less than 90 degree d) 180 degree View Answer 10. A synchronous generator is operating with a Ef=1.40pu. This machine having Xs of 1.2pu, is delivering a synchronous power of 0.5pu to the bus. Web26. In turbo-alternators, smooth cylindrical type rotors used have long axial length because (a) it gives smooth running of the rotor (b) it reduces windage loss (c) …

100+ Electrical MCQ Questions in Induction Motor Electrical4u

Web20. The synchronous motor meets increase in load by taking more armature current as. (a) the rotor pole falls back relative to the stator pole causing an increase in motor current. (b) the back emf decreases causing an increase in motor current. (c) rotating field is strengthened causing an increase in motor current. WebSolutions for Chapter 6 Problem 3MCQ: The rotors preferred for alternators coupled to hydraulic turbines are(a) salient pole type(b) cylindrical rotor type(c) solid rotor type(d) … 3d 表皮皮肤模型 https://craftach.com

Construction of Alternator Electrical4U

WebOn the other hand, cylindrical rotors are used for turbo alternators running at high speed as 3600 RPM or 1800 RPM. ④ Alternators are also called Synchronous generators … WebIn alternators, cylindrical pole type rotors are generally used with prime movers of a) High speed b) Low speed c) Medium speed d) Both low and high speed Ans: (a) 9. An alternator is said to be overexcited when it is operating at a) Unity power factor b) Leading power factor c) Lagging power factor d) Either lagging or leading power factor WebAlternators can be classified into the following two types according to its rotor construction Smooth cylindrical type alternator Salient pole alternator 5. Why do cylindrical Alternators operate with steam turbines? Steam turbines are found to operate at fairly good efficiency only at high speeds. 3d 裸眼技术

Alternator Rotor Types MCQ [Free PDF] - Objective …

Category:Cylindrical Rotor Alternator Questions - Electrical Machines

Tags:Cylindrical rotor alternators have mcq

Cylindrical rotor alternators have mcq

Alternator Objective Questions With Explanation Part-1 - Electrical MCQ

WebFeb 24, 2012 · The cylindrical rotor alternators are generally designed for 2-pole type giving very high speed of Or 4-pole type running at a speed of Where, f is the frequency … http://www.electricalunits.com/mcq-alternator-and-synchronous-motors-page-3/

Cylindrical rotor alternators have mcq

Did you know?

WebThe field windings of cylindrical type rotor are connected in series to the slip rings through which they are excited by the DC exciter. The top portion of the slot is covered with the … WebThis type of Rotor is used for steam-driven alternator i.e turbo alternator which runs at very high speed. The Rotor is made up of smooth solid forgings of alloy steel cylinder having the number of slots along the outer periphery. The field windings of cylindrical type rotor are connected in series to the slip rings through which they are excited by the DC …

WebJun 12, 2015 · Salient Pole Type Rotor - Synchronous Generator - MCQs with answers Q1. In synchronous machine, poles are made up of thick steel laminations. In salient pole type rotor a. Poles are projected out from the surface of the rotor b. The unslotted portions of the cylinder itself acts as the poles c. Both (a) and (b) d. None of the above WebJun 6, 2024 · Show Explanation Ques 52. Two alternators rated 40 MVA and 60 MVA respectively are working in parallel and supplying a total load of 80 MW. Speed regulation of both the alternator is 5%. The load sharing …

WebJun 6, 2024 · An alternator is generating power at 210 V per phase while running at 1500 RPM. If the speed of an alternator drops to 1000 rpm the generated voltage per phase will be. Ques.23. An alternator is said to … WebThe rotor is the rotating part of the alternator. It is made in a cylindrical shape that has copper windings also known as field winding. The field windings are electromagnets that generate the necessary rotating …

WebIn this MCQ you can learn and practice Cylindrical Rotor Alternator objective quiz questions to test your knowledge on electrical machines. …

WebAug 3, 2024 · Difference between Cylindrical Rotor and Salient Pole Rotor Synchronous Generator - A synchronous generator, also called alternator, is a most widely used … 3d 裸眼图WebMar 6, 2024 · Smooth Cylindrical type rotor is generally used for high-speed alternators or turbo-alternators. This is because: These rotors have small diameter and long axial … 3d 視力回復 立体視 効果WebFeb 24, 2012 · Now let us derive various equations for the power flow the cylindrical rotor alternator. In order to derive various power equation for an alternator let us substitute voltage source E 1 equal to the excitation voltage (E f), voltage source E 2 equals to the terminal voltage (V t), inductive impedance of the above circuit equals to synchronous … 3d 製造現場での活用WebAug 19, 2024 · Home alternator MCQ Alternator Objective Questions With Explanation Part-1 August 19, 2024 1. The speed of a 4-pole 60 Hz synchronous machine will be A. 1800 r.p.m. B. 2400 r.p.m. C. 3000 r.p.m. D. 3600 r.p.m. Answer: A. 1800 r.p.m. Explanation: In a synchronous machine, Frequency, fs = 60 Hz Number of poles = 4 … 3d 製図 書き方WebCylindrical rotor alternators have a) Large length to diameter ratio b) Small length to diameter ratio c) Vertical configuration d) None of these Ans: (a) 25. In an alternator, the … 3d 観葉植物 無料WebAlternator MCQ Synchronous Generator MCQ 151. Consider the following statements Salient pole alternators have small diameters and large axial lengths. Cylindrical rotor alternators have a distributed winding. Cylindrical rotor alternators are wound for … 3d 設計師WebJun 22, 2024 · A simple brief definition and explanation. The main story is on the way: salient pole vs cylindrical pole. Cylindrical (non-salient) pole or round-rotor or a drum rotor usually can be found in higher speed … 3d 製作依頼